Products

Residential Air-Conditioners

Features

Multi-Split System Product Lineup

Connectable Indoor Units : System 1 to 3 (max)

SCM60YS-W

Specification

  • Cooling Source (kw) : 6.0 (1.1(min) - 8.4 (Max)

  • Power Consumption (kw) : 1.2

  • COP (w/w) : 5

  • Running Current (A) : 5.3

  • Outdoor Unit Airflow Rate (M3/min) : 36.1

  • Sound Pressure Level (dB(A)) : 50

  • Exterior Dimensions(HxWxD) (mm) : 640x850x290

  • Net Weight (KG) : 47.5

  • Piping Size (Liquid/Gas) (mm) : 6.35 x 3 / 9.52 x 3

  • Vertical Height Differences (m) : Max 15

Connectable Indoor Units : System 1 to 4 (max)

SCM80YS-W

Specification

  • Cooling Source (kw) : 8.0 (2.2(min) - 10.6 (Max)

  • Power Consumption (kw) : 1.64

  • COP (w/w) : 4.88

  • Running Current (A) : 7.5

  • Outdoor Unit Airflow Rate (M3/min) : 49.4

  • Sound Pressure Level (dB(A)) : 51

  • Exterior Dimensions(HxWxD) (mm) : 750 x 880 x 340

  • Net Weight (KG) : 60.5

  • Piping Size (Liquid/Gas) (mm) : 6.35 x 4 / 9.52 x 4

  • Vertical Height Differences (m) : Max 20

Single-Split 1:1 System Product Lineup

SRC10YVS-W

Specification

  • Cooling Source (kw) : 2.5

  • Power Consumption (kw) : 0.51

  • COP (w/w) : 4.9

  • Running Current (A) : 2.6

  • Outdoor Unit Airflow Rate (M3/min) : 26.5

  • Sound Pressure Level (dB(A)) : 45

  • Exterior Dimensions(HxWxD) (mm) : 540x780(+62)x290

  • Net Weight (KG) : 33.5

  • Piping Size (Liquid/Gas) (mm) : 6.35/9.52

  • Vertical Height Differences (m) : Max 10

SRC13YVS-W

Specification

  • Cooling Source (kw) : 3.5

  • Power Consumption (kw) : 0.82

  • COP (w/w) : 4.27

  • Running Current (A) : 3.9

  • Outdoor Unit Airflow Rate (M3/min) : 31.5

  • Sound Pressure Level (dB(A)) : 49

  • Exterior Dimensions(HxWxD) (mm) : 540x780(+62)x290

  • Net Weight (KG) : 33.5

  • Piping Size (Liquid/Gas) (mm) : 6.35/9.52

  • Vertical Height Differences (m) : Max 10

SRC18YVS-W

Specification

  • Cooling Source (kw) : 5.2

  • Power Consumption (kw) : 1.39

  • COP (w/w) : 3.6

  • Running Current (A) : 6.1

  • Outdoor Unit Airflow Rate (M3/min) : 34.5

  • Sound Pressure Level (dB(A)) : 47

  • Exterior Dimensions(HxWxD) (mm) : 640x800(+71)x290

  • Net Weight (KG) : 40.5

  • Piping Size (Liquid/Gas) (mm) : 6.35/12.7

  • Vertical Height Differences (m) : Max 15

SRC24YVS-W

Specification

  • Cooling Source (kw) : 7.1

  • Power Consumption (kw) : 1.84

  • COP (w/w) : 3.86

  • Running Current (A) : 8.2

  • Outdoor Unit Airflow Rate (M3/min) : 55

  • Sound Pressure Level (dB(A)) : 65

  • Exterior Dimensions(HxWxD) (mm) : 750x880(+88)x340

  • Net Weight (KG) : 58

  • Piping Size (Liquid/Gas) (mm) : 6.35/15.88

  • Vertical Height Differences (m) : Max 20

Indoor Units - for combination with outdoor units for Multi-Split system and Single Split system

SRK10YVS-W

Specification

  • Cooling (KW) : 2.5

  • AirFlow Rate (m3/min) : 10.9/8.4/5.3

  • Sound Pressure Level (dB) : 39/31/22

  • Exterior Dimension (HxWxD) (mm) : 290 x 870 x 230

  • Pipe Size (Liquid/Gas) : 6.35 / 9.52

  • Vertical Height Differences (m) : Max 10m

  • Refrigerant Type : R32

SRK13YVS-W

Specification

  • Cooling (KW) : 3.5

  • AirFlow Rate (m3/min) : 12.3/9.1/7.0

  • Sound Pressure Level (dB) : 43/34/27

  • Exterior Dimension (HxWxD) (mm) : 290 x 870 x 230

  • Pipe Size (Liquid/Gas) : 6.35 / 9.52

  • Vertical Height Differences (m) : Max 10m

  • Refrigerant Type : R32

SRK18YVS-W

Specification

  • Cooling (KW) : 5.2

  • AirFlow Rate (m3/min) : 12.8/10.5/6.8

  • Sound Pressure Level (dB) : 43/36/28

  • Exterior Dimension (HxWxD) (mm) : 290 x 870 x 230

  • Pipe Size (Liquid/Gas) : 6.35 / 12.70

  • Vertical Height Differences (m) : Max 15m

  • Refrigerant Type : R32

SRK24YVS-W

Specification

  • Cooling (KW) : 7.1

  • AirFlow Rate (m3/min) : 20.5/18.6/16.2

  • Sound Pressure Level (dB) : 43/40/36

  • Exterior Dimension (HxWxD) (mm) : 339 x 1,197 x 262

  • Pipe Size (Liquid/Gas) : 6.35 / 15.88

  • Vertical Height Differences (m) : Max 20m

  • Refrigerant Type : R32

Where To Buy : Our Sale Channels

Web Catalog

Residential (RAC)

We introduce our Next Generation Refrigerant R32 low GWP RAC air conditioners. The capacity range from 2.5 - 7.1kW. Multi-split systems combination are available for system 2 to 4 indoor units connectivity. The long reach and 3D airflow make for smooth operation, coupled with wifi enable is ideal for smart modern homes. With an Allergen clear filter that can inactivate the Covid19 virus, and Nano filter that captures 99% of PM2.5 particles, the unit keeps clean air circulating throughout the room.

  • Multi Split System

  • Single Split System

Commercial (PAC)

The Commercial (PAC) range from Mitsubishi Heavy Industries (MHI) is ideal for air conditioning offices, shops, restaurants, and bars, as well as other commercial use. The newly introduced R32 range (June 2022) offers you a wide selection of models for your installation needs. Our PAC systems are available with a wide range of indoor units, with capacities ranging from 5 - 14 kW. Supporting features include high energy efficiency, quiet noise, New Draft Prevention Panel, Motion Sensor and advanced touch screen Remote Controller are key winning features.

Super-Multi (KX)

Our Super-multi VRF (KX) systems offer simple and flexible solutions for commercial and industrial applications, with up to 80 indoor units in a single system. Sophisticated control, combined with a high level of technology, ensures reduced energy consumption and high efficiency rates. The KX range starts with 11.2 kW cooling capacity up to a combination system of 168.0 kW. KX is suitable for a wide range of applications from an individual apartment to entire multi-storey buildings. KX incorporates highly sophisticated control to condition multiple indoor areas, for applications where the building orientation creates heat gain/loss on each side of the building.