Products

Package Air-Conditioners - FD Series

Features

Draft Prevention

Energy Saving  

Motion Sensor 

RC-EX3 (New) 

Package Product LineUp - Outdoor

FDC50YNA-W

Specification

  • Exterior Dimensions(HxWxD) (mm) : 595 x 780 x 290

  • Net Weight (KG) : 32

  • Piping Size (Liquid/Gas) (mm) : 6.35 / 12.7

  • Vertical Height Differences (m) : 15

  • Refrigerant Line (1 way) Length (m) : 25

  • Recommended Breaker Size (A) : 20

FDC71YNA-W

Specification

  • Exterior Dimensions(HxWxD) (mm) : 640 x 800 x 290

  • Net Weight (KG) : 37

  • Piping Size (Liquid/Gas) (mm) : 6.35 / 12.7

  • Vertical Height Differences (m) : 20

  • Refrigerant Line (1 way) Length (m) : 30

  • Recommended Breaker Size (A) : 20

FDC100YNA-W

Specification

  • Exterior Dimensions(HxWxD) (mm) : 750 x 880 x 340

  • Net Weight (KG) : 51

  • Piping Size (Liquid/Gas) (mm) : 6.35 / 15.88

  • Vertical Height Differences (m) : 20

  • Refrigerant Line (1 way) Length (m) : 50

  • Recommended Breaker Size (A) : 30

FDC125YNA-W

Specification

  • Exterior Dimensions(HxWxD) (mm) : 845 x 970 x 370

  • Net Weight (KG) : 67.5

  • Piping Size (Liquid/Gas) (mm) : 9.52 / 15.88

  • Vertical Height Differences (m) : 20

  • Refrigerant Line (1 way) Length (m) : 50

  • Recommended Breaker Size (A) : 30

FDC140VSA-W (3 Phase)

Specification

  • Exterior Dimensions(HxWxD) (mm) : 845 x 970 x 370

  • Net Weight (KG) : 78

  • Piping Size (Liquid/Gas) (mm) : 9.52 / 15.88

  • Vertical Height Differences (m) : 50 / 15

  • Refrigerant Line (1 way) Length (m) : 50

  • Recommended Breaker Size (A) : 30

Indoor Units

Cassette Model (FDT)

Ducted Model (FDU/FDUM)

Suspense Model (FDE)

FDT50YA-W

Specification

  • NEA Label Tick : 3

  • Cooling KW (min/rated/max) : 1.6/5.3/5.7

  • Power Consumption : 1.38

  • Dimension HxWxD(mm) Indoor Unit : 236x840x840

  • Dimension HxWxD(mm) Panel : 35x950x950

  • AirFlow Rate (m3/min) : 22/16/13/10

  • Panel model : T-PSA-5BW-E

  • Std Remote Controller (Wireless) : RCN-T-5BW-E

  • Optional (Wired RC) : RC-E5

  • Refrigerant Type : R32

FDT125YA-W

Specification

  • NEA Label Tick : 2

  • Cooling KW (min/rated/max) : 3.1/12.5/12.8

  • Power Consumption : 3.87

  • Dimension HxWxD(mm) Indoor Unit : 298x840x840

  • Dimension HxWxD(mm) Panel : 35x950x950

  • AirFlow Rate (m3/min) : 38/28/25/18

  • Panel model : T-PSA-5BW-E

  • Std Remote Controller (Wireless) : RCN-T-5BW-E

  • Optional (Wired RC) : RC-E5

  • Refrigerant Type : R32

FDUM50YA-W

Specification

  • Cooling KW (min/rated/max) : 1.6/5.3/5.7

  • Power Consumption : 1.59

  • Dimension HxWxD(mm) : 280X750X635

  • AirFlow Rate (m3/min) : 13/10/9/8

  • External Static Pressure (Pa) : Std : 35, Max : 100

  • Std Remote Controller (Wireless) : RCN-KIT4-E2

  • Optional (Wired RC) : RC-E5

  • Refrigerant Type : R32

FDU140VH

Specification

  • Cooling KW (min/rated/max) : 5.0/13.6/14.5

  • Power Consumption : 5.13

  • Dimension HxWxD(mm) : 280X1,370x740

  • AirFlow Rate (m3/min) : 48/35/28/22

  • External Static Pressure (Pa) : Std : 60, Max : 200

  • Std Remote Controller (Wireless) : RCN-KIT4-E2

  • Optional (Wired RC) : RC-E5

  • Refrigerant Type : R32

FDE140VH

Specification

  • Cooling KW (min/rated/max) : 5.0/13.6/14.5

  • Power Consumption : 5.05

  • Dimension HxWxD(mm) : 250/1,620/690

  • AirFlow Rate (m3/min) : 34/29/23/18

  • Std Remote (Wireless) : RCN-E-E3

  • Optional (Wired RC) : RC-E5

  • Refrigerant Type : R32

FDT71YA-W

Specification

  • NEA Label Tick : 2

  • Cooling KW (min/rated/max) : 1.3/7.1/7.7

  • Power Consumption : 2.0

  • Dimension HxWxD(mm) Indoor Unit : 236x840x840

  • Dimension HxWxD(mm) Panel : 35x950x950

  • AirFlow Rate (m3/min) : 28/18/15/12

  • Panel model : T-PSA-5BW-E

  • Std Remote Controller (Wireless) : RCN-T-5BW-E

  • Optional (Wired RC) : RC-E5

  • Refrigerant Type : R32

FDT140VH (3Phase)

Specification

  • NEA Label Tick : NA

  • Cooling KW (min/rated/max) : 5.0/13.5/14.5

  • Power Consumption : 4.79

  • Dimension HxWxD(mm) Indoor Unit : 298x840x840

  • Dimension HxWxD(mm) Panel : 35x950x950

  • AirFlow Rate (m3/min) : 38/29/26/19

  • Panel model : T-PSA-5BW-E

  • Std Remote Controller (Wireless) : RCN-T-5BW-E

  • Optional (Wired RC) : RC-E5

  • Refrigerant Type : R32

FDUM71YA-W

Specification

  • Cooling KW (min/rated/max) : 1.3/7.1/7.7

  • Power Consumption : 2.2

  • Dimension HxWxD(mm) : 280X950x635

  • AirFlow Rate (m3/min) : 24/19/15/10

  • External Static Pressure (Pa) : Std : 35, Max : 100

  • Std Remote Controller (Wireless) : RCN-KIT4-E2

  • Optional (Wired RC) : RC-E5

  • Refrigerant Type : R32

FDT100YA-W

Specification

  • NEA Label Tick : 3

  • Cooling KW (min/rated/max) : 2.0/10.5/11.5

  • Power Consumption : 2.8

  • Dimension HxWxD(mm) Indoor Unit : 298x840x840

  • Dimension HxWxD(mm) Panel : 35x950x950

  • AirFlow Rate (m3/min) : 37/26/23/17

  • Panel model : T-PSA-5BW-E

  • Std Remote Controller (Wireless) : RCN-T-5BW-E

  • Optional (Wired RC) : RC-E5

  • Refrigerant Type : R32

FDU100YA-W

Specification

  • Cooling KW (min/rated/max) : 2.0/10.5/11.5

  • Power Consumption : 3.1

  • Dimension HxWxD(mm) : 280X1,368x738

  • AirFlow Rate (m3/min) : 36/28/25/19

  • External Static Pressure (Pa) : Std : 40, Max : 200

  • Std Remote Controller (Wireless) : RCN-KIT4-E2

  • Optional (Wired RC) : RC-E5

  • Refrigerant Type : R32

Where To Buy : Our Sale Channels

Web Catalog

Residential (RAC)

We introduce our Next Generation Refrigerant R32 low GWP RAC air conditioners. The capacity range from 2.5 - 7.1kW. Multi-split systems combination are available for system 2 to 4 indoor units connectivity. The long reach and 3D airflow make for smooth operation, coupled with wifi enable is ideal for smart modern homes. With an Allergen clear filter that can inactivate the Covid19 virus, and Nano filter that captures 99% of PM2.5 particles, the unit keeps clean air circulating throughout the room.

  • Multi Split System

  • Single Split System

Commercial (PAC)

The Commercial (PAC) range from Mitsubishi Heavy Industries (MHI) is ideal for air conditioning offices, shops, restaurants, and bars, as well as other commercial use. The newly introduced R32 range (June 2022) offers you a wide selection of models for your installation needs. Our PAC systems are available with a wide range of indoor units, with capacities ranging from 5 - 14 kW. Supporting features include high energy efficiency, quiet noise, New Draft Prevention Panel, Motion Sensor and advanced touch screen Remote Controller are key winning features.

Super-Multi VRF (KX)

Our Super-multi VRF (KX) systems offer simple and flexible solutions for commercial and industrial applications, with up to 80 indoor units in a single system. Sophisticated control, combined with a high level of technology, ensures reduced energy consumption and high efficiency rates. The KX range starts with 11.2 kW cooling capacity up to a combination system of 168.0 kW. KX is suitable for a wide range of applications from an individual apartment to entire multi-storey buildings. KX incorporates highly sophisticated control to condition multiple indoor areas, for applications where the building orientation creates heat gain/loss on each side of the building.